8200-M411-O1 Rev D y 210/215 Installation & Technical 1 210 and 215 WEIGHT INDICATOR Installation and Technical Manual
8200-M411-O1 Rev D y 210/215 Installation & Technical 6 INSTALLATION Before beginning installation of your Model 210/215 Weight Indicator, make ce
8200-M411-O1 Rev D y 210/215 Installation & Technical 7 CAUTION! Disconnect any external load cell power supply before connecting load cells to
8200-M411-O1 Rev D y 210/215 Installation & Technical 8 INSTALLATION, CONT. Load Cell Cable Shield Wire Connection for RFI Suppression 1. After a
8200-M411-O1 Rev D y 210/215 Installation & Technical 9 INSTALLATION, CONT. Serial I/O Cable Installation The 210/215 indicators may be connected
8200-M411-O1 Rev D y 210/215 Installation & Technical 10 INSTALLATION, CONT. For completely isolated outputs, J11 must be open (positioned on one
8200-M411-O1 Rev D y 210/215 Installation & Technical 11 INSTALLATION, CONT. Main PCB Figure No. 8
8200-M411-O1 Rev D y 210/215 Installation & Technical 12 INSTALLATION, CONT. Main PCB Jumpers J1 - BATTERY CHARGE MODE (210 Only) Place jumper J1
8200-M411-O1 Rev D y 210/215 Installation & Technical 13 KEYPAD FUNCTIONS The Model 210/215 is equipped with a 22-key keypad. The keypad is used
8200-M411-O1 Rev D y 210/215 Installation & Technical 14 KEYPAD FUNCTIONS, CONT. ON/OFF KEY This key performs two functions. Pressing it when the
8200-M411-O1 Rev D y 210/215 Installation & Technical 15 KEYPAD FUNCTIONS, CONT. Consecutive Number If the consecutive number displayed is correc
8200-M411-O1 Rev D y 210/215 Installation & Technical 2
8200-M411-O1 Rev D y 210/215 Installation & Technical 16 KEYPAD FUNCTIONS, CONT. The 210/215 includes support for visual tickets. Visual tickets
8200-M411-O1 Rev D y 210/215 Installation & Technical 17 KEYPAD FUNCTIONS, CONT. ASTERISK KEY This key is used for several functions. During Set
8200-M411-O1 Rev D y 210/215 Installation & Technical 18 ANNUNCIATORS Annunciators are turned on to indicate that the display is in the mode corre
8200-M411-O1 Rev D y 210/215 Installation & Technical 19 ANNUNCIATORS OVER/PWC3 (210 Only) This annunciator is used to signal that the displayed
8200-M411-O1 Rev D y 210/215 Installation & Technical 20 SETUP AND CALIBRATION Your Model 210/215 indicator has been thoroughly tested and calibra
8200-M411-O1 Rev D y 210/215 Installation & Technical 21 SETUP AND CALIBRATION, CONT. Pressing the calibration switch at any prompt will return y
8200-M411-O1 Rev D y 210/215 Installation & Technical 22 SETUP AND CALIBRATION, CONT. !;> (Legal For Trade) Press the ENTER key to show the cu
8200-M411-O1 Rev D y 210/215 Installation & Technical 23 SETUP AND CALIBRATION, CONT. $> (Capacity) Press the ENTER key to show the current
8200-M411-O1 Rev D y 210/215 Installation & Technical 24 SETUP AND CALIBRATION, CONT. 3`6';`> X, Y (Digital Output) Press the ENTER key to
8200-M411-O1 Rev D y 210/215 Installation & Technical 25 SETUP AND CALIBRATION, CONT. `6> (Auto Shutoff) The Automatic Shutoff feature will
8200-M411-O1 Rev D y 210/215 Installation & Technical ITABLE OF CONTENTS SPECIFICATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - -
8200-M411-O1 Rev D y 210/215 Installation & Technical 26 SETUP AND CALIBRATION, CONT. `@`3 (`@`3) - Analog to Digital Filtering 3!;> (Digit
8200-M411-O1 Rev D y 210/215 Installation & Technical 27 SETUP AND CALIBRATION, CONT. FILTER SETTING RECOMMENDATIONS Non Critical Sample Rate If
8200-M411-O1 Rev D y 210/215 Installation & Technical 28 SETUP AND CALIBRATION, CONT. ! (!) - Calibration With ! (!) displayed, press th
8200-M411-O1 Rev D y 210/215 Installation & Technical 29 SETUP AND CALIBRATION, CONT. Dual-Point with Zero (First Zero) Calibration !> – Fi
8200-M411-O1 Rev D y 210/215 Installation & Technical 30 SETUP AND CALIBRATION, CONT. Dual-Point without Zero (False Zero) Calibration !> –
8200-M411-O1 Rev D y 210/215 Installation & Technical 31 SETUP AND CALIBRATION, CONT. Single-Point for Zero Only (Only Zero) Calibration !>
8200-M411-O1 Rev D y 210/215 Installation & Technical 32 SETUP AND CALIBRATION, CONT. *-6 (*-6) - Serial Input/Output With *-6 (*-6) displayed,
8200-M411-O1 Rev D y 210/215 Installation & Technical 33 SETUP AND CALIBRATION, CONT. If SMA is selected, the data will be transmitted in the fol
8200-M411-O1 Rev D y 210/215 Installation & Technical 34 SETUP AND CALIBRATION, CONT. If WI110 is selected, the data will be transmitted in the fo
8200-M411-O1 Rev D y 210/215 Installation & Technical 35 SETUP AND CALIBRATION, CONT. ;9:> (Threshold Weight) Press the ENTER key to show the
8200-M411-O1 Rev D y 210/215 Installation & Technical II FCC COMPLIANCE STATEMENT WARNING! This equipment generates uses and can radiate radio fr
8200-M411-O1 Rev D y 210/215 Installation & Technical 36 SETUP AND CALIBRATION, CONT. $9-0; ($9-0;) - Print Tab Settings With $9-0; ($9-0;) disp
8200-M411-O1 Rev D y 210/215 Installation & Technical 37 SETUP AND CALIBRATION, CONT. 0;> (Net Weight Print Location) Press the ENTER key to
8200-M411-O1 Rev D y 210/215 Installation & Technical 38 SETUP AND CALIBRATION, CONT. `*$0 (*$0) - Fine Span Adjustment NOTE! The *$0 and
8200-M411-O1 Rev D y 210/215 Installation & Technical 39 SETUP REVIEW The 210/215 indicators allow several operational parameters to be reviewed
8200-M411-O1 Rev D y 210/215 Installation & Technical 40 ACCUMULATORS To view the NET accumulator: 1. Press the ASTERISK key then the NET/GROSS
8200-M411-O1 Rev D y 210/215 Installation & Technical 41 BEFORE YOU CALL FOR SERVICE The 210/215 indicators have been designed to provide you wit
8200-M411-O1 Rev D y 210/215 Installation & Technical 42 ERROR CODES The 210/215 indicators are equipped with software that indicates when an erro
8200-M411-O1 Rev D y 210/215 Installation & Technical 43 ERROR CODES, CONT. < (HuH?) UNITS key pressed in an attempt to perform a unit conv
8200-M411-O1 Rev D y 210/215 Installation & Technical 44 AXLE WEIGHER MODE OPERATION After placing the wheel load weighers on the ground in front
8200-M411-O1 Rev D y 210/215 Installation & Technical 45 AXLE WEIGHER MODE OPERATION, CONT. Additional Features If you wish to also record the to
8200-M411-O1 Rev D y 210/215 Installation & Technical 1 SPECIFICATIONS Unless otherwise noted, the specifications apply to both the Model 210 and
8200-M411-O1 Rev D y 210/215 Installation & Technical 46 PART IDENTIFICATION (210 Rear Enclosure Sub Assembly) ITEM NO. QTY. PART NUMBER DESCRIPT
8200-M411-O1 Rev D y 210/215 Installation & Technical 47 PART IDENTIFICATION (210 Rear Enclosure Sub Assembly)
8200-M411-O1 Rev D y 210/215 Installation & Technical 48 PART IDENTIFICATION (210 Front Enclosure Sub Assembly) ITEM NO. QTY. PART NUMBER DESCRIP
8200-M411-O1 Rev D y 210/215 Installation & Technical 49 PART IDENTIFICATION (210 Final Assembly) ITEM NO. QTY. PART NUMBER DESCRIPTION 1 1 593G
8200-M411-O1 Rev D y 210/215 Installation & Technical 50 PART IDENTIFICATION (215 Rear Enclosure Sub Assembly) ITEM NO. QTY. PART NUMBER DESCRIPT
8200-M411-O1 Rev D y 210/215 Installation & Technical 51 PART IDENTIFICATION (215 Rear Enclosure Sub Assembly)
8200-M411-O1 Rev D y 210/215 Installation & Technical 52 PART IDENTIFICATION (215 Front Enclosure Sub Assembly) ITEM NO. QTY. PART NUMBER DESCRIP
8200-M411-O1 Rev D y 210/215 Installation & Technical 53 PART IDENTIFICATION (215 Final Assembly) ITEM NO. QTY. PART NUMBER DESCRIPTION 1 1 593G
8200-M411-O1 Rev D y 210/215 Installation & Technical 54
8200-M411-O1 Rev D y 210/215 Installation & Technical 55 APPENDIX A: MODEL 210DC AND 215DC The Models 210DC and 215DC have been created to change
8200-M411-O1 Rev D y 210/215 Installation & Technical 2 SPECIFICATIONS, CONT. Unless otherwise noted, the specifications apply to both the Model
8200-M411-O1 Rev D y 210/215 Installation & Technical 1 STATEMENT OF LIMITED WARRANTY WARRANTY TERMS Cardinal Scale Manufacturing Company warrant
8200-M411-O1 Rev D y 210/215 Installation & Technical 2 PRODUCT TYPE TERM MATERIAL AND WORKMANSHIP LIGHTNING DAMAGE See note 9 WATER DAMAGE See n
8200-M411-O1 Rev D y 210/215 Installation & Technical 3 APPLICABLE LIMITATIONS AND REQUIREMENTS 1. This warranty applies only to the original pur
8200-M411-O1 Rev D y 210/215 Installation & Technical 4 EXCLUSIONS This warranty does not include replacement of consumable of expendable parts.
Addendum to the 200, 205, 210 and 215 Installation and Technical Manual TEST MODE This addendum is to inform you of the TEST MODE feature in the 200,
Addendum to the 200, 205, 210 and 215 Installation and Technical Manual This addendum is to inform you of changes to the 200, 205, 210 and 215 Weig
CONTINUOUS DATA OUTPUT FORMATS TOLEDO Beginning with version 2.6.1 of the firmware, the Toledo output has been expanded to provide a selection between
CONTINUOUS DATA OUTPUT FORMATS, CONT. RANGER 5000 FORMAT A Beginning with version 2.6.1 of the firmware, the Ranger 5000 Format A has been added to th
200, 205, 210 and 215 Rev 2.6.1 Addendum 4 CONTINUOUS DATA OUTPUT FORMATS, CONT. GEDGE 1650 FORMAT 4 Beginning with version 2.6.1 of the firmware, the
Addendum to the 200, 205, 210 and 215 Installation and Technical Manual This addendum is to inform you of changes to the 200, 205, 210 and 215 Weig
8200-M411-O1 Rev D y 210/215 Installation & Technical 3 EUROPEAN DECLARATION OF CONFORMITY Manufacturer: Cardinal Scale Manufacturing Company P
8200-M411-O1 Rev D y 210/215 Installation & Technical 1
8200-M411-O1 Rev D y 210/215 Installation & Technical 4 PRECAUTIONS Static Electricity CAUTION! This device contains static sensitive circuit ca
8200-M411-O1 Rev D y 210/215 Installation & Technical 5 SITE PREPARATION REQUIREMENTS, CONT. Electrical Power The 210/215 indicators have been de
Comentários a estes Manuais