Detecto CS-6 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Digitalizar e Imprimir Detecto CS-6. Detecto CS-6 User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 47
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
USER MANUAL
CS 5000
Model 11674xx
USA
Garrett Metal Detectors
Security Division
1881 W. State Street
Garland, Texas 75042-6797 USA
Phone: 1.800.234.6151
Fax: 1.972.494.1881
Website: garrett.com
International
Garrett Metal Detectors
International Security Division
1881 W. State Street
Garland, Texas 75042-6797 USA
Phone: 1.972.494.6151
Fax: 1.972.494.1881
Website: garrett.com
Vista de página 0
1 2 3 4 5 6 ... 46 47

Resumo do Conteúdo

Página 1 - USER MANUAL

USER MANUALCS 5000Model 11674xxUSAGarrett Metal DetectorsSecurity Division1881 W. State StreetGarland, Texas 75042-6797 USAPhone: 1.800.234.6151Fax:

Página 2

2.2.5 + AND - These touchpads will be used to increase or decrease various numerical settings and for certainOn/Off functions.2.2.6 PROGRAM When this

Página 3 - MANUFACTURER CAUTION

2.3.3 BATTERY PACK MODULE (OPTIONAL)This module, which includes two (2) 12v batteries and charging circuitry that comprise the optionalbattery pack, w

Página 4 - MEDICAL SAFETY

3. INSTALLATION INSTRUCTIONS 3.1 SITE SELECTIONThe Garrett CS 5000 should be located on a level, stable floor with no large metal items within three(3

Página 5 - TABLE OF CONTENTS

3.2.2 Install the Power Cord completely through one of the channels at the top of either of the Panelsas shown below. A channel can be found in each

Página 6

3.2.5 Use the remaining screws and washers to attach the Crosspiece to the two panels, as shown3.2.6 Tighten all eight screws securely with a slotted

Página 7

4. SELF-DIAGNOSTIC TESTSThe Garrett CS 5000 LCD panel provides valuable information concerning the operation of this unitand the self-diagnostic progr

Página 8 - 2. CONTROLS & MODULES

4.1.3 FATAL ERRORSThe system continuously performs several of the tests described above. Errors 1,4 and 5 severelylimit or prohibit the operation of

Página 9

5. INSTALLATION ADJUSTMENTSThe Installation Adjustment Mode, which can be accessed only through use of a four-digit code(Access Code #2), permits the

Página 10 - User Manual

ting with least interference as observed by fluctuation of the Bar Graph.Press ACCESS for the next adjustment or OPERATE to return to normal operation

Página 11

6. SUPERVISOR ADJUSTMENTSSeveral adjustments may be made at the Supervisor’s Level (Access Code #1). These are primari-ly program/sensitivity settings

Página 13

2. By inhibiting the alarm when no one is in its archway, the IR Analysis greatly minimizes nuisance alarms. In instances where there is movement of

Página 14

7. SUPERVISOR RESPONSIBILITIES7.1 CALIBRATIONCalibration settings of walk-through metal detectors are dependent upon individualsecurity screening requ

Página 15 - 4. SELF-DIAGNOSTIC TESTS

be established, and this testing system should be adhered to consistently.Included in the test procedure should be the requirement that the tester be

Página 16

7.4.2. APPLICATIONS:• High: High sensitivity; low traffic volume• Medium: High Sensitivity; high traffic volume• Standard: Normal sensitivity; high tr

Página 17

8. TECHNICAL SPECIFICATIONS8.1 ELECTRONICSDigital-controlled pulse induction metal detector with microprocessors utilized in both detection andcontrol

Página 18

8.11 REGULATORY INFORMATIONThe Garrett CS 5000 meets or exceeds detection requirements of the National Institute of LawEnforcement and Criminal Jus

Página 19 - 6. SUPERVISOR ADJUSTMENTS

9. MAINTENANCE & REPAIR9.1 PERIODIC MAINTENANCEPeriodic maintenance of the equipment requires only inspection for loose or damaged parts andcleani

Página 20

CS 5000 User Manual©2005 GARRETT METAL DETECTORS 27 PN 1530100 REV E2216871512914 235136POWER SUPPLY &BATTERY BACK-UP CON

Página 21

CS 5000 User Manual© 2005 GARRETT METAL DETECTORS 28 PN 1530100 REV E171820101921114

Página 22

9.4. REPLACEMENT PARTSCS 5000 User Manual©2005 GARRETT METAL DETECTORS 29 PN 1530100 REV EITEM DESCRIPTION PART # QTY1 Access

Página 23

MANUFACTURER CAUTIONRead Thoroughly Before OperatingCAUTION! Use of this equipment in a manner not specified by the manufacturer may result in damage

Página 24 - 8. TECHNICAL SPECIFICATIONS

9.5 WARRANTYGarrett Electronics, Inc. (“Garrett”) warrants that this CS 5000 weapons/metal detector is protectedby the following limited parts and lab

Página 25

10. OPERATING INSTRUCTIONSThis Manual is designed to provide all necessary information required for operation of the GarrettCS 5000 walk-through metal

Página 26 - 9. MAINTENANCE & REPAIR

10.4 READY LIGHTThis green light appears when full power has been turned on and the unit is ready to detect. The lightwill also indicate when an indiv

Página 27

10.8.3 COUNTERSince the current traffic count of the CS 5000 is usually displayed, this touchpad will be needed onlyfor resetting the counter. Pressin

Página 28

10.12 READY LIGHTThe green READY light, located at the top center of the Control Panel indicates that the CS 5000 isoperating. When the green light is

Página 29

10.16 NUISANCE ALARMS Any metal detector will occasionally register what is called a “nuisance alarm,” triggered by electri-cal or mechanical noise fr

Página 30

10.18 COUNTERIf the current traffic count is not being reported on the LCD display, press this touchpad to view it.Pressing and holding this touchpad

Página 31 - 10. OPERATING INSTRUCTIONS

11 ADDITIONAL INFORMATION11.1 OPERATIONS WORK SHEETLocation: ____________________Serial Number: ____________________Version: ____________________Date

Página 32

11.2 PROGRAMSNote: Although different settings are required for different applications, the manufacturerfinds Program D most effective for high volume

Página 33

11.2.5 PROGRAM C• Custom program designed to detect ferrous and conductive objects equally.• This program is optimized for the three-gun test of the F

Página 34

MEDICAL SAFETYGarrett Metal Detectors makes every effort to ensure its products are safe for use. Extensive research by Garretthas produced no informa

Página 35

11.3 MULTIPLE UNIT OPERATIONThere are several options for installation of multiple units in close proximity. The following list ofexamples will be hel

Página 36

Procedure:• Disconnect units from power line;• Open Access Door of Detection Unit;• Remove three (3) screws that hold controller cover;• Use synchroni

Página 37 - 11 ADDITIONAL INFORMATION

11.4.2.1 Case I: Use internal power• Disconnect from AC power;• Open Access Door of detection unit;• Remove three (3) screws that hold controller cov

Página 38

11.5.1 INSTALLATION• With power disconnected locate archway and console in their desired locations;• Locate connecting wire and protect from tamperi

Página 39

7. Reconnect the Power Supply Module and Battery Pack Module as shown;8. Reassemble the system and test.11.7 STABILIZER BASE INSTALLATIONTOOLS REQUIRE

Página 40

Caution: Adjust the width of the unit at the bottom of the panels to 30” (762mm) BEFORE making theholes in the next step.11.8 ELECTRICAL WIRING REQUIR

Página 41

CS 5000 User Manual© 2005 GARRETT METAL DETECTORS 46 PN 1530100 REV E

Página 42

© 2005 GARRETT METAL DETECTORS - The Global Leader of Metal Detection Products and Training - 1530100 REV E

Página 43

TABLE OF CONTENTS1. GENERAL DESCRIPTION 62. CONTROLS & MODULES 82.1 DISPLAY PANEL 82.2 TOUCHPADS 92.3 INTERNAL MODULES 103. INSTALLATION INSTRUCTI

Página 44

1. CS 5000 GENERAL DESCRIPTIONThe Garrett CS 5000 Walk-Through Metal Detector features microprocessor-controlled circuitry and LCD presentation of all

Página 45

allows supervisors to keep a log of all changes that are ever made as well as any unsuccessful attemptsto change them. In addition, a tamper indicati

Página 46

2. CONTROLS & MODULES2.1 DISPLAY PANEL2.1.1 LED BAR GRAPHThis LED display at the top of the Control Panel indicates the detection intensity which

Página 47

2.2 TOUCHPADSEight touchpads on the overhead Control Panel perform all control functions:2.2.1 STANDBYWhen this touchpad is pressed, the unit goes int

Comentários a estes Manuais

Sem comentários